Boiler pressure: too low, too high, and
why it will not stay put
Most of the calls we get about pressure are not really about the gauge. They are about a boiler that has stopped, or radiators that will not warm up, or hot water that has gone cold, and the pressure is simply the thing the boiler is complaining about.
We aim for about 1.5 bar on the gauge, read with the boiler off and settled for a few minutes, and anywhere between 1.5 and 2 is fine. If the pressure is low the boiler will usually shut itself down, and on a system boiler that means you lose the heating and the stored hot water together. Topping it up is often something you can do yourself. Where it gets less straightforward is when it will not stay topped up, or when it climbs too high, and those two point at different things.
What the gauge should read
We aim for roughly 1.5 bar, and we tell customers anywhere between 1.5 and 2 is fine. We would not want it higher than it should be, which means heading towards 3 bar or into the red on the gauge.
That is a slightly different answer from the one you will find most places, which is to fill to 1 bar. We do not like 1 bar. If the pressure drops slightly, and it will move a little with a change in the weather or as the system settles, you are back with the same problem within weeks. Starting at 1.5 gives the system somewhere to go.
Read the gauge with the boiler off and settled for a few minutes, because the pump affects the reading while it is running.
What the gauge is telling you
| What you see | What it usually means | What to do |
|---|---|---|
| Low, and the boiler has stopped | Not enough pressure in the sealed system for the boiler to run | Top it up to 1.5 at the filling loop, with the boiler off |
| 1.5 to 2, boiler off and settled | Where it should be | Nothing |
| Low again within weeks | Water is getting out: a leak on the pipework or radiators (sometimes under the floor, out of sight), a relief valve passing, an expansion vessel that has lost its charge, or a pinhole in the heat exchanger draining through the condensate | Have it looked at, because topping up only treats the symptom |
| Climbs when the heating runs, heading towards 3 bar or into the red | Usually the expansion vessel | Have it looked at, and do not keep topping it up |
| Creeping up with nobody touching the filling loop | The filling loop not closed properly, or on a combi a pinhole in the plate heat exchanger | Check both filling loop valves are closed; if they are, it needs an engineer |
Where the filling loop actually is
This is the part that stops people, and it is not their fault.
On a combi the filling loop is usually underneath the boiler. On a system boiler with an unvented cylinder it very often is not, and it will be by the cylinder instead. We had exactly this a few weeks ago on a video call with a customer whose pressure had dropped to 0.3. She was standing at the boiler looking for something that was never going to be there. Once we knew it was a system boiler with an unvented cylinder we asked her to show us the cylinder, and the loop was right there.
If you have been looking under your boiler and finding nothing, go and look at the cylinder.
Topping it up
The loop has two valves on it. Open them one at a time and watch the gauge, then close them both again when you get where you want to be. Then go back to the boiler and check the reading there.
On that call the first fill brought it to just over 1, which is where a lot of people would stop. We asked her to go again and bring it up to 1.5.
One thing worth saying, because we have been called out for it more than once. If you are reaching about under the boiler looking for the filling loop, be careful what you close. There is often a gas lever down there as well, and turning that off by mistake will leave you with a boiler that will not light at all.
When it will not stay there
Topping up a boiler that keeps losing pressure is treating the symptom. If you are filling it every few weeks something is letting water out, and the usual places are a leak on the pipework or radiators, a pressure relief valve passing, or an expansion vessel that has lost its charge.
The one that catches people is a leak you will never see. If the heating pipework is leaking under the floorboards, and there are often deep foundations under there, nothing shows up in the house at all. No damp patch, no stain on a ceiling, nothing. The gauge is the only thing telling you about it.
We have also found the pressure going out through the condensate, where there is a pinhole in the main heat exchanger and the system water is quietly draining away with everything else. Again, nothing to find on the floor.
None of these get better on their own, and only one of them is anything like a visible problem.
When it is too high
Pressure that climbs higher than it should, towards 3 bar or into the red, or that rises when the heating comes on and does not come back down, usually points at the expansion vessel.
If the gauge is filling up on its own without anybody opening the filling loop, there are two things behind that. The common one is the filling loop itself not having closed properly, so the system keeps quietly taking on mains water, and that one costs nothing to check. The other is a pinhole in the plate heat exchanger on a combi, which lets cold mains water cross into the heating side and pushes the pressure up the same way.
When it is not a job to do yourself
Topping up the pressure is fine. Finding out why it will not hold is not, and neither is anything involving the expansion vessel, the relief valve or the gas side of the boiler.
If you are topping it up more than once or twice a year, it is worth having somebody look at why.
"Very good work. I called them for my house boiler and central heating system problem, they recommended best solution and fixed the issue on the same day. Very neat work and reasonable charges."
The short version
We aim for about 1.5 bar, read with the boiler off and settled, and anywhere between 1.5 and 2 is fine, because at 1 bar the small drop every system has puts you straight back into a low pressure fault. If it is low, top it up at the filling loop, which on a combi is usually under the boiler and on a system boiler with an unvented cylinder is very often by the cylinder, and be careful not to close the gas lever by mistake. If you are topping it up more than once or twice a year something is letting water out, and if it climbs towards 3 bar or into the red the expansion vessel is the usual cause, and both of those want an engineer.
Quick answers
What pressure should my boiler be at?
Why does my boiler keep losing pressure?
Why is my boiler pressure too high?
Can I top up the boiler pressure myself?
Where is the filling loop on a system boiler?
Is 2 bar too high for a boiler?
Why does my boiler pressure go up when the heating is on?
Pressure will not hold, or keeps climbing?