Your boiler will not light, and
it is probably not the part you are dreading

When a boiler locks out on an ignition fault, the first thing most people are told is that it is the PCB or the gas valve. Those are both real, and they are both expensive, and in our experience they are near the end of the list rather than the start of it.

Ravinder Singh, Founder of DGN GAS
Ravinder Singh - Founder, DGN GASGas Safe registered · Baxi Approved · Vaillant Advance Platinum · Worcester Bosch Installer
The Short Answer

An ignition fault means the boiler tried to light and could not confirm that it did. There are about five things that cause it, two of them cost nothing to rule out, and the expensive ones are the last two on the list. It is worth going through them in order.

The Detail

First: is the gas actually on

This sounds too simple to be worth saying, and it is one of the most common things we find.

We have been to jobs where the gas had been turned off by mistake. The meter is often tucked away under the stairs, and if somebody has been putting a vacuum cleaner in and out of that cupboard it is very easy to catch the lever on the emergency control valve without noticing.

The other one happens at the boiler itself. There is usually a gas lever underneath it that closes by hand, and we have been called out to boilers that would not light because somebody had been reaching about under there looking for the filling loop to top up the pressure, and closed the wrong lever.

So before anything else, look at both. The lever should be in line with the pipe, not across it.

The Detail

Second: the condensate pipe

Every condensing boiler drains a small amount of water away as it runs, and if that pipe is blocked or frozen the water backs up and the boiler stops. In cold weather this is extremely common.

You may hear a gurgling noise from the boiler before it locks out, and that gurgle is worth paying attention to because it is often the only warning you get.

If the pipe is frozen and you can reach it safely from the ground, warming it gently along its length will usually clear it and the boiler will often restart.

The Detail

Third: the flue

A blockage in the flue, for whatever reason, will cause an ignition fault. This is not something to go poking at, but it is on the list of things we check, and it is worth knowing that a flue problem shows up as an ignition fault rather than as anything obviously flue-shaped.

The Detail

Fourth: the gas valve

Here we are into engineer territory. The question is whether the boiler is getting enough gas and whether the valve is opening properly when there is a demand for heating or hot water. That needs testing rather than looking at.

The Detail

Fifth: the ignition side

The electrodes have to be in good condition and correctly positioned, and the cables and harness running to them have to be sound. A harness can be checked with a multimeter, and that is generally where we find the answer when the first four have come back clear.

The Detail

And then the PCB

Last. Not first.

The reason we go through it in this order is that the first two cost nothing and take a minute, and the last one is the most expensive part in the appliance. Working backwards from the expensive thing is how people end up paying for a board when the gas lever was off.

The Detail

The fault codes

Different manufacturers give this fault a different code, and it varies by model within a brand as well.

On a Vaillant an ignition fault shows as F28 or F29. On a Baxi it is E133, and on their newer models E.01.04. On an Ideal it is L2. Other manufacturers use their own codes, so it is worth checking the book that came with your appliance, or the panel inside the case.

The code tells you what the boiler could not do. It does not tell you which of the five things above caused it, which is why the order matters.

The Detail

When to call someone

The first two on this list are yours. Everything from the flue onwards is a Gas Safe job, and the ignition side in particular involves working on the gas carrying parts of the appliance.

You can check an engineer's registration at https://www.gassaferegister.co.uk

What Customers Say
★★★★★

"Ravinder is a good and trustworthy gas engineer. Recently replaced my gas valve on my boiler. Was very happy with the work. Decided to also engage their services to fit a new hob and extractor. Reasonably priced and honest workers. Will be using them for all my future gas related work."

Kamps Mamtora
Google Review · gas valve replacement
Common Questions

Quick answers

What does an ignition fault mean?
The boiler tried to light and could not confirm that it did, so it locked out to stay safe. It does not tell you which part caused it.
What is a Vaillant F28 fault?
F28, and F29 on some models, is Vaillant's ignition fault. It means the boiler attempted to light and failed, and the cause could be anything from the gas being turned off to a component inside the appliance.
Is an ignition fault always the PCB?
No, and it is worth ruling out the cheap things first. We check whether the gas is on, then the condensate pipe, then the flue, then the gas valve, then the electrodes and harness. The PCB is last, because it is the most expensive part in the boiler.
Can I fix an ignition fault myself?
You can check whether the gas has been turned off at the meter or under the boiler, and whether the condensate pipe has frozen. Everything past that is work for a Gas Safe registered engineer.
What is a Baxi E133 fault?
E133 is Baxi's ignition fault code, shown as E.01.04 on newer models. As with any brand, the code says the boiler failed to light without saying why.